TheĀ Canon imageRunner 2230, 2270, 2830, 2870, 3025 E000-0001 Error Code is caused by a high temperature reading in the fusing assembly. Below find the service manual information on this problem along with some helpful tips. Also, find links to get a replacement fuser and links to reset the error code.

Canon imageRunner 2230, 2270, 2830, 2870, 3025 E000-0001 Error Code

Canon imageRunner 2230, 2270, 2830, 2870, 3025 Fixing/Fuser Assembly – FM3-1278-000, FM2-0356-000

Service Manual Advice for the Canon imageRunner 2230, 2270, 2830, 2870, 3025 E000-0001 Error Code

E000-0001 :Ā The temperature of the fixing assembly is abnormally high.
While startup control is underĀ way, the reading of the mainĀ thermistor is less than 30 deg CĀ continuously for 200 msec orĀ more 1 sec after the start ofĀ power supply.
While startup control is underĀ way, the reading of the mainĀ thermistor is less than 70 deg CĀ continuously for 200 msec orĀ more 2 sec after the start ofĀ power supply.
While startup control is underĀ way, the reading of the mainĀ thermistor is less than 120 deg CĀ continuously for 200 msec 6 secĀ after the start of power supply.
The startup control does not endĀ 30 sec after the start of powerĀ supply.
Reset the condition in serviceĀ mode:
COPIER>FUNCTION>CLEAR>Ā ERR.
Replace the main thermistor.