Below you will find the service manual information for the Canon-imageRUNNER-3035 E000 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3035 E000 0001 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3035 E000 0001 Error Code

E000 0001
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply.
The startup control does not end 30 sec after the start of power supply.

Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor.
Replace the DC controller PCB.


Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95

Canon imageRUNNER 3035 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3035 E000, E001, E002, E003, Error Code Reset

If you’re looking at this write-up and have information about this error and want to share please make sure to leave a comment down the page. Or, if you have read this article and have additional questions then ask. If I have information about the difficulty then I will answer back.

Realize, not every error is simply identical. What corrects the trouble one occasion will possibly not eliminate it the next occasion. While the details in this blog post hails from the service manual and most often ought to get your device functioning, now and again additional variables may be in play.