Canon-imageRUNNER-3035 E001 0002 Error Code

 

Canon-imageRUNNER-3035 E001 0002 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3035 E001 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3035 E001 0002 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3035 E001 0002 Error Code

E001 0002
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the sub thermistor.
Replace the DC controller PCB.


Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95

Canon imageRUNNER 3035 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3035 E000, E001, E002, E003, Error Code Reset

If you’re looking at this write-up and have knowledge about this error and would wish to contribute be sure to leave a comment beneath. Or, if you have read this article and have additional questions then ask. If I have experience with the trouble then I will respond.

Realize, not every error is simply the same. What treats the trouble one time may possibly not eliminate it the next time. While the guidance in this writing hails from the service manual and most often ought to get your equipment ready to go, at times additional factors might be in play.

We will be happy to hear your thoughts

Leave a reply

Shopping cart