Below you will find the service manual information for the Canon imageRUNNER 2018i E003 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2018i E003 0001 Error Code

Service Manual Instructions for the Canon imageRUNNER 2018i E003 0001 Error Code

E003 0001
Description :
Abnormally low temperature (detected by sub thermistor)

Causes :
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.

Solutions :
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DC controller PCB.



Canon FM0-0160-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $314.95

Canon imageRUNNER 2018i Fuser Removal and Replacement FM0-0160-000, FM3-3651-000


Understand, not every error is exactly identical. What fixes the problem one time may not eliminate it the next occasion. While the help and advice in this write-up originates from the service manual and most often ought to get your machine operating, in some cases additional variables can be in play.

If you are looking over this page and have experience with this problem and would like to share please leave a comment down below. Or, if you have read this article and have further questions then ask. If I have exposure to the problem then I will answer back.