Canon imageRUNNER 2018i E052 0000 Error Code

 

Canon imageRUNNER 2018i E052 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2018i E052 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2018i E052 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2018i E052 0000 Error Code

E052 0000
Description :
Erroneous connection to duplex unit

Causes :
Disconnection of the duplex unit was detected after power-on, detection of normal connection to the duplex unit, and start of communication.

Solutions :
Check the connectors of the duplex unit and DC controller PCB.
Replace the duplex controller PCB.
Replace the DC controller PCB.



Understand, not every error is exactly alike. What corrects the difficulty one time might not exactly fix it the next occasion. While the material in this page is obtained from the service manual and in most cases ought to get your piece of equipment operational, occasionally additional circumstances could possibly be in play.

If you are looking over this page and have exposure to this fault and would wish to share please be sure to leave a comment down the page. Or, if you have read this article and have more questions then ask. If I have knowledge about the trouble then I will reply.

We will be happy to hear your thoughts