Canon imageRUNNER 2018i E003 0000 Error Code Instructions
Below you will find the service manual information for the Canon imageRUNNER 2018i E003 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it.
Service Manual Instructions for the Canon imageRUNNER 2018i E003 0000 Error Code
E003 0000
Description :
Abnormally low temperature (detected by main thermistor)
Causes :
After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Solutions :
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DC controller PCB.
Canon FM0-0160-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $314.95
Canon imageRUNNER 2018i Fuser Removal and Replacement FM0-0160-000, FM3-3651-000
Understand, not every error is exactly identical. What remedies the issue one occasion may possibly not take care of it the next time. While the tips in this piece of content is obtained from the service manual and in most cases ought to get your unit functioning, from time to time other things might be in play.
If you are looking over this page and have experience with this fault and wish to share be sure to leave a comment underneath. Or, if you have read this article and have more questions then ask. If I have knowledge about the issue then I will answer back.