Canon imageRUNNER 2018i E002 0000 Error Code

 

Canon imageRUNNER 2018i E002 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2018i E002 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2018i E002 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2018i E002 0000 Error Code

E002 0000
Description :
Low temperature during temperature control.

Causes :
The target temperature is not reached during temperature control.

Solutions :
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DC controller PCB.



Canon FM0-0160-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $314.95

Canon imageRUNNER 2018i Fuser Removal and Replacement FM0-0160-000, FM3-3651-000


Understand, not every error is exactly identical. What remedies the situation one time might not exactly fix it the next time. While the advice in this document obtain from the service manual and usually ought to get your equipment ready to go, at times other variables can be in play.

If you are looking over this page and have experience with this error and want to contribute please make sure to leave a comment below. Or, if you have read this article and have additional questions then ask. If I have exposure to the issue then I will reply.

We will be happy to hear your thoughts

Leave a reply

Shopping cart