Below you will find the service manual information for the Canon imageRUNNER 2018i E001 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2018i E001 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2018i E001 0000 Error Code

E001 0000
Description :
Abnormally high temperature (detected by main thermistor)

Causes :
The main thermistor detected an abnormally high temperature (240 deg C) during temperature control.

Solutions :
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DC controller PCB.



Canon FM0-0160-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $314.95

Canon imageRUNNER 2018i Fuser Removal and Replacement FM0-0160-000, FM3-3651-000


Understand, not every error is exactly the same. What remedies the issue one occasion might not exactly resolve it the next time. While the specifics in this writing derives from the service manual and typically should get your unit operating, sometimes other causes may be in play.