Canon imageRUNNER 1730iF E001 0002 Error Code

 

Canon imageRUNNER 1730iF E001 0002 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 1730iF E001 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1730iF E001 0002 Error Code

Service Manual Instructions for the Canon imageRUNNER 1730iF E001 0002 Error Code

E001 0002
Description :
Detection of overheating of Fixing Assembly

Causes :
The Sub Thermistor detected 295 deg C or higher for 200msec or longer on end.

Solutions :
1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).


Canon FM1-B701-000 Fuser (Fixing) Unit – 110 / 120 Volt (Genuine) – $279.95

from: Precision Roller

Canon imageRUNNER 1730 E000, E001, E002, E003, Error Code Reset


Canon imageRUNNER 1730 Fuser Removal and Replacement

Bear in mind, not every error is absolutely alike. What corrects the trouble one time will possibly not solve it the next time. While the tips in this writing is taken from the service manual and oftentimes should get your equipment working, occasionally other elements may be in play.