Canon i-SENSYS MF6680dn E001 0 Error Code

 

Canon i-SENSYS MF6680dn E001 0 Error Code Instructions

Below you will find the service manual information for the Canon i-SENSYS MF6680dn E001 0 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon i-SENSYS MF6680dn E001 0 Error Code

Service Manual Instructions for the Canon i-SENSYS MF6680dn E001 0 Error Code

E001 0
Description :
E001 0 Abnormally high temperature (detected by main thermistor)
Causes :
The main thermistor detected an abnormally high temperature during temperature control.

Solutions :
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the Engine controller PCB.


HP RM1-6405-000cn Fuser (Fixing) Unit – 120 Volt (Genuine) – $129.95

Canon imageCLASS D1120 Fuser Removal and Replacement RM1-6405-000, FM4-3436-000

Remember that, not every error is completely alike. What remedies the trouble one occasion may not eliminate it the next time. While the advice in this writing is taken from the service manual and usually ought to get your unit ready to go, on occasion additional circumstances can be in play.

If you are reading this blog post and have exposure to this malfunction and want to make a contribution please leave a comment underneath. Or, if you have read this article and have additional questions then ask. If I have experience with the trouble then I will answer back.