Canon imageCLASS D1180 E003 1 Error Code

 

Canon imageCLASS D1180 E003 1 Error Code Instructions

Below you will find the service manual information for the Canon imageCLASS D1180 E003 1 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageCLASS D1180 E003 1 Error Code

Service Manual Instructions for the Canon imageCLASS D1180 E003 1 Error Code

E003 1
Description :
E003 1 Abnormally low temperature (detected by sub thermistor)
Causes :
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.

Solutions :
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the Engine controller PCB.