0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem.
Defective FAX control PWB.
Replace the fax control PWB and check for correct operation.

0070 FAX control PWB incompatible detection error
Abnormal detection of FAX control PWB incompatibility
In the initial communication with the FAX control PWB, any normal communication command is not transmitted.
Defective FAX software.
Install the fax software.
Defective FAX control PWB.
Replace the fax control PWB and check for correct operation.

0100 Backup memory device error
Defective flash memory.
Replace the main PWB and check for correct operation
Defective main PWB.
Replace the main PWB and check for correct operation

0120 MAC address data error For data in which the MAC address is invalid.
Defective flash memory.
Replace the main PWB and check for correct operation
Defective engine PWB.
Replace the engine PWB and check for correct operation

0130 Backup memory read/ write error (main PWB)
Defective flash memory.
Replace the main PWB and check for correct operation
Defective main PWB.
Replace the main PWB and check for correct operation

0140 Backup memory data error (main PWB)
Defective flash memory.
Replace the main PWB and check for correct operation
Defective main PWB.
Replace the main PWB and check for correct operation

0150 Engine PWB EEPROM error
Detecting engine PWB
EEPROM communication error.
Improper installation engine PWB EEPROM.
Check the installation of the EEPROM and remedy if necessary.
Defective engine PWB.
Replace the engine PWB and check for correct operation
Device damage of EEPROM.
Contact the Service Administrative Division.

0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters.
Data damage of EEPROM.
Contact the Service Administrative Division.
Defective PWB. Replace the main PWB or the engine PWB and check for correct operation

0180 Machine number mismatch
Machine number of main and engine does not match.
Data damage of EEPROM.
Contact the Service Administrative Division.

0420 Paper feeder communication error
Communication error between engine PWB and optional paper feeder.
Improper installation paper feeder.
Follow installation instruction carefully again.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Paper feeder interface and connect-L PWB (YC2)
Connect-L PWB (YC6) and engine PWB (YC504)
Defective engine PWB.
Replace the engine PWB and check for correct operation
Defective PF main PWB.
Replace the PF main PWB (Refer to the service manual for the paper feeder).

0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB.
Defective FAX software.
Install the fax software.
Defective FAX control PWB.
Replace the FAX control PWB

0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
The battery is disconnected from the main PWB.
Check visually and remedy if necessary
Defective main PWB.
Replace the main PWB and check for correct operation

0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally
performed even if the data transfer was retried the specified times.
Improper installation FAX control PWB.
Reinstall the FAX control PWB
Defective FAX control PWB or main PWB.
Replace the FAX control PWB or main PWB and check for correct operation

0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB.
Defective FAX control PWB.
Replace the FAX control PWB and check for correct operation

1010 Lift motor error
During driving the lift motor, a motor overcurrent signal is detected for 5 s.
This error is detected five times successively.
Defective bottom plate elevation mechanism in the cassette.
Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Lift motor and connect-R PWB (YC8) Connect-R PWB (YC2) and engine PWB (YC502)
Defective drive transmission system of the lift motor.
Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective lift motor. Replace the lift motor
Defective engine PWB or connect-R PWB.
Replace the engine PWB or connect-R PWB and check for correct operation

2000 Main motor steady-state error
The main motor ready input is not given for 2 s during the main motor is ON.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Main motor and engine PWB (YC501)
Defective drive transmission system of the main motor.
Check if the rollers and gears rotate smoothly.
If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective main motor.
Replace the main motor.
Defective engine PWB.
Replace the engine PWB and check for correct operation

2200 Drum motor steady-state error
The drum motor ready input is not given for 2 s during the drum motor is ON.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Drum motor and engine PWB (YC11)
Defective drive transmission system of the drum motor.
Check if the rollers and gears rotate smoothly.
If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective drum motor.
Replace the drum motor.
Defective engine PWB.
Replace the engine PWB and check for correct operation

3100 ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Home position sensor and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8) ISU motor and main PWB (YC1004)
Defective home position sensor.
Replace the home position sensor.
Defective ISU motor.
Replace the ISU motor.
Defective CCD PWB.
Replace the scanner unit
Defective main PWB.
Replace the main PWB and check for correct operation

3200 Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If one, remedy or replace the cable.
LED PWB (YC1) and LED drive PWB (YC2)
LED drive PWB (YC1) and CCD PWB (YC3)
CCD PWB (YC2) and main PWB (YC8)
Defective exposure lamp or LED drive PWB.
Replace the scanner unit
Defective CCD PWB.
Replace the scanner unit
Defective main PWB.
Replace the main PWB and check for correct operation

3300 AGC error
After AGC, correct input is not obtained at CCD.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Inverter PWB (YC101) and CCD PWB (YC3)
CCD PWB (YC2) and main PWB (YC8)
Defective exposure lamp or inverter PWB.
Replace the scanner unit
Defective CCD PWB.
Replace the scanner unit
Defective main PWB.
Replace the main PWB and check for correct operation

3500 Communication error between scanner and ASIC
An error code is detected.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
CCD PWB (YC2) and main PWB (YC8)
Defective CCD PWB.
Replace the scanner unit
Defective main PWB.
Replace the main PWB and check for correct operation

4000 Polygon motor synchronization error

The polygon motor ready input is not given for 10 s
during the polygon motor is ON.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Laser scanner unit and main PWB (YC14)
Defective polygon motor.
Replace the laser scanner unit
Defective main PWB.
Replace the main PWB and check for correct operation

4200 BD steady-state error
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Laser scanner unit and main PWB (YC16)
Defective laser scanner unit.
Replace the laser scanner unit
Defective main PWB.
Replace the main PWB and check for correct operation

4700 VIDEO ASIC device error
Mismatch of reading data from two locations occurs eight times successively.
Mismatch between writing data and reading data occurs eight times successively.
Defective connector cable or poor
contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable.
Main PWB (YC13) and engine PWB (YC12)
Defective main PWB or engine PWB.
Replace the main PWB or the engine PWB and check for correct operation

5100 Main charger high-voltage error

Five pages have been printed with the main charger output short-circuited.
Drum unit installed incorrectly.
Verify harness is not pinched.
Engine PWB installed incorrectly.
Verify harness is not pinched.
Defective engine PWB.
Replace the engine PWB and check for correct operation

6000 Broken fuser heater wire

The temperature does not reach 100°C/212°F after the fuser heater has been turned on continuously for 30 s.
The temperature does not rise by 1°C/1.8°F after the fuser heater lamp has been turned on continuously for
15 s during warm-up or at standby.(Only when the detection temperature is less than 200°C.)
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Fuser heater and power source PWB (YC102)
Fuser unit and engine PWB (YC506)
Deformed connector pin.
Defective triac.
Fuser thermostat triggered.
Reinsert the fuser unit
Broken fuser heater wire.
Replace the fuser unit

6020 Abnormally high fuser thermistor 2 temperature
The temperature of the fuser thermistor 2 detects 250°C/482°F or more continuously for 3 s.
Shorted fuser thermistor 2.
Replace the fuser unit
Deformed connector pin.
Defective triac.
Defective engine PWB.
Replace the engine PWB and check for correct operation

6030 Broken fuser thermistor 2 wire

average AD value input from fuser thermistor 2 for 1.8 seconds is less than one. (Only when the detection
temperature is 50°C or more.)
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Fuser unit and engine PWB (YC506)
Deformed connector pin.
Defective triac.
Broken fuser thermistor 2 wire.
Replace the fuser unit
Fuser thermostat triggered.
Reinsert the fuser unit
Broken fuser heater wire.
Replace the fuser unit

6000/6020/6030 Combined
Broken fuser heater wire
Abnormally high fuser thermistor temperature
Broken fuser thermistor wire
Deformed connector pin.
If the I/F connector pins of the fuser unit and the main unit are deformed owing to foreign matters, such as paper dusts, replace the connectors or the units including the connectors.
Defective triac. Remove the power cord and check that the resistance between terminals T1 and T2 of the triac TRA51 is of several Mega-Ohms and not shorted If failed, replace the power source PWB

6220 Abnormally high fuser thermistor 1 temperature

The temperature of the fuser thermistor 1 detects 255°C/491°F or more continuously for 3 s.
Shorted fuser thermistor 1.
Replace the fuser unit
Defective engine PWB.
Replace the engine PWB and check for correct operation

6230 Broken fuser thermistor 1 wire
average AD value input from fuser thermistor 1 for 1.8 seconds is less than one.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Fuser unit and engine PWB (YC506)
Broken fuser thermistor 1 wire.
Replace the fuser unit
Fuser thermostat triggered.
Reinsert the fuser unit
Broken fuser heater wire.
Replace the fuser unit

6400 Zero-cross signal error

The zero-cross signal does not reach the engine PWB for more than 2 s.
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Power source PWB (YC103) and connect-L PWB (YC1)
Connect-L PWB (YC8) and engine PWB (YC503)
Defective power source PWB.
Replace the power source PWB and check for correct operation Defective engine PWB.
Replace the engine PWB and check for correct operation

7000 Toner motor lock error

During driving the toner motor, a motor over current signal is detected for 5 s.
Lump of toner inside toner container.
Replace the toner container.
Defective drive transmission system of the toner motor.
Replace the developing unit
Defective toner motor.
Replace the developing unit
Defective engine PWB.
Replace the engine PWB and check for correct operation
7410 Drum unit non- installing error
The drum unit is not installed or not installed properly.
The drum PWB EEPROM does not communicate normally.
The drum unit is not installed.
Install the drum unit
Defective connector cable or poor contact in the connector.
Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Drum PWB (YC1) and connect-L PWB (YC3)
Defective drum PWB EEPROM.
Replace the drum unit
Defective engine PWB.
Replace the engine PWB and check for correct operation

9500 BRU communication error
IPU PWB error Contact the Service Administrative Division.

9510 BRU PWB error

9520 BRU PWB data error

F000 Main PWB – operation panel PWB communication error
Defective main PWB.
Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective operation panel PWB.
Replace the operation panel PWB.

F020 Main PWB RAM checksum error
Defective main memory (RAM) on the main PWB.
Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective expanded memory (DIMM).
Replace the expanded memory (DIMM).

F040 Main PWB – engine PWB communication error

Defective main PWB.
Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective engine PWB.
Replace the engine PWB.

F041 Main PWB – scanner communication error
Defective main PWB.
Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.

F050 Engine ROM checksum error

Defective engine PWB.
Replace the engine PWB and check for correct operation

F051 Scan engine ROM checksum error

Defective engine PWB.
Replace the engine PWB and check for correct operation