Below you will find the service manual information for the Canon imageRUNNER 2025i E002 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it.
Service Manual Instructions for the Canon imageRUNNER 2025i E002 0000 Error Code
E002 0000
Description :
Low temperature during temperature control.
Causes :
The target temperature is not reached during temperature control.
Solutions :
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DC controller PCB.
Canon FM0-0160-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $314.95
Canon imageRUNNER 2025i Fuser Removal and Replacement FM0-0160-000, FM3-3651-000
Try to remember, not every error is absolutely identical. What fixes the difficulty one time may possibly not take care of it the next time. While the advice in this post is inspired by the service manual and in most cases should get your equipment operational, at times other variables can be in play.