Canon imageRUNNER 2022i E261 0000 Error Code

 

Canon imageRUNNER 2022i E261 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2022i E261 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2022i E261 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2022i E261 0000 Error Code

E261 0000
Description :
Zero-cross signal error

Causes :
If failed to detect zero-cross signal cycle of the power supply when initializing.
When the input of the zero-signal failed continuously for three seconds while controlling the temperature adjustment.

Solutions :
Replace the power supply PCB.
Replace the DC controller PCB.




Try to remember, not every error is completely the same. What treats the problem one time might not exactly solve it the next time. While the information in this written piece is obtained from the service manual and normally ought to get your equipment operating, from time to time additional variables could possibly be in play.

If you are looking over this short article and have exposure to this error and want to make a contribution please make sure to leave a comment underneath. Or, if you have read this article and have additional questions then ask. If I have knowledge about the difficulty then I will reply.

We will be happy to hear your thoughts

Leave a reply

Shopping cart