Canon-imageRUNNER-3570 E064 0005 Error Code

 

Canon-imageRUNNER-3570 E064 0005 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3570 E064 0005 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3570 E064 0005 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3570 E064 0005 Error Code

E064 0005
Description :
The voltage of the power supply is faulty (high-voltage error).

Causes :
While output is being generated, the AD value of the transfer output voltage is 0 (DEC) for 100 msec 2 times in sequence.
(However, after output, it is not detected for 100 msec.)



Solutions :
Replace the high-voltage power supply.
Replace the DC controller PCB.



If you’re reading this piece of content and have knowledge of this malfunction and would wish to make a contribution be sure to leave a comment underneath. Or, if you have read this article and have further questions then ask. If I have experience with the trouble then I will answer.

Try to remember, not every error is totally the same. What corrects the condition one occasion might not exactly solve it the next occasion. While the tips in this blog is inspired by the service manual and typically should get your device operational, now and again other variables can be in play.