Below you will find the service manual information for the Canon imageCLASS MF6160dw E003 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageCLASS MF6160dw E003 0000 Error Code

Service Manual Instructions for the Canon imageCLASS MF6160dw E003 0000 Error Code

E003 0000
Description :
Abnormal low temperature of Fixing Assembly
Causes :
It was detected that the temperature of the Fixing Assembly was abnormally low.

Solutions :
1. Check the connector between the Fixing Assembly and the DC Controller PCB.
2. Replace the Fixing Assembly.
3. Replace the DC Controller PCB.


HP RM1-6405-000cn Fuser (Fixing) Unit – 120 Volt (Genuine) – $129.95

Canon imageCLASS MF6160dw Fuser Removal and Replacement RM1-6405-000, FM4-3436-000

Understand, not every error is entirely the same. What fixes the malfunction one time may possibly not eliminate it the next time. While the details in this writing derives from the service manual and usually ought to get your product working, now and again additional factors may be in play.

If you are looking at this blog post and have knowledge about this malfunction and desire to share be sure to leave a comment below. Or, if you have read this article and have more questions then ask. If I have information about the problem then I will answer.