Below you will find the service manual information for the Canon imageCLASS MF5950dw E003 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageCLASS MF5950dn E003 0000 Error Code

Service Manual Instructions for the Canon imageCLASS MF5950dw E003 0000 Error Code

E003 0000
Description :
Abnormal low temperature of Fixing Assembly
Causes :
It was detected that the temperature of the Fixing Assembly was abnormally low.

Solutions :
1. Check the connector between the Fixing Assembly and the DC Controller PCB.
2. Replace the Fixing Assembly.
3. Replace the DC Controller PCB.


HP RM1-6405-000cn Fuser (Fixing) Unit – 120 Volt (Genuine) – $129.95

Canon imageCLASS MF5950dw Fuser Removal and Replacement RM1-6405-000, FM4-3436-000