Below you will find the service manual information for the Canon imageCLASS MF5880dn E000 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageCLASS MF5880dn E000 0000 Error Code

Service Manual Instructions for the Canon imageCLASS MF5880dn E000 0000 Error Code

E000 0000
Description :
Error in temperature rising of Fixing Assembly
Causes :
Temperature of the Fixing Assembly did not reach a certain temperature within the specified period of time.

Solutions :
1. Check the connector between the Fixing Assembly and the DC Controller PCB.
2. Replace the Fixing Assembly.
3. Replace the Engine Controller PCB.


HP RM1-6405-000cn Fuser (Fixing) Unit – 120 Volt (Genuine) – $129.95

Canon imageCLASS MF5880dn Fuser Removal and Replacement RM1-6405-000, FM4-3436-000

Bear in mind, not every error is totally alike. What corrects the issue one time might not solve it the next occasion. While the guidance in this writing originates from the service manual and in most cases ought to get your device operating, in some cases other elements could possibly be in play.

If you’re reading this piece of content and have information about this malfunction and would like to contribute be sure to leave a comment down the page. Or, if you have read this article and have further questions then ask. If I have information about the difficulty then I will reply.