Canon imageRUNNER 2545 E225 0000 Error Code

 

Canon imageRUNNER 2545 E225 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2545 E225 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2545 E225 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2545 E225 0000 Error Code

E225 0000
Description :

Causes :
The light intensity of the CCD during shading is under the specified level.


Solutions :
1.Disconnect and then connect the flexible cable.
2.Replace the flexible cable.
3.Replace the CCD Unit.
4.Replace the Relay PCB (PCB2).
5.Replace the Main Controller PCB (PCB1).


Please remember, not every error is simply identical. What treats the complication one time might not take care of it the next occasion. While the specifics in this text comes from the service manual and in most cases should get your product up and running, on occasion other reasons may be in play.

If you’re looking at this piece of content and have experience with this problem and wish to make a contribution be sure to leave a comment beneath. Or, if you have read this article and have further questions then ask. If I have information about the trouble then I will reply.