Canon imageRUNNER 2535I E225 0000 Error Code

 

Canon imageRUNNER 2535I E225 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2535I E225 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2535I E225 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2535I E225 0000 Error Code

E225 0000
Description :

Causes :
The light intensity of the CCD during shading is under the specified level.


Solutions :
1.Disconnect and then connect the flexible cable.
2.Replace the flexible cable.
3.Replace the CCD Unit.
4.Replace the Relay PCB (PCB2).
5.Replace the Main Controller PCB (PCB1).


Realize, not every error is totally identical. What corrects the condition one time might not take care of it the next occasion. While the specifics in this written piece derives from the service manual and generally ought to get your product functioning, from time to time other variables could possibly be in play.

If you’re looking at this write-up and have knowledge of this fault and wish to make a contribution please make sure to leave a comment down the page. Or, if you have read this article and have further questions then ask. If I have experience with the difficulty then I will answer back.

We will be happy to hear your thoughts

Leave a reply