Canon imageRUNNER 2535 E805 0002 Error Code

 

Canon imageRUNNER 2535 E805 0002 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2535 E805 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2535 E805 0002 Error Code

Service Manual Instructions for the Canon imageRUNNER 2535 E805 0002 Error Code

E805 0002
Description :

Causes :
When lock signal is detected for 5 sec while the Exhaust Fan (Front) (FAN4) is stopped
* The same condition is detected after the error retry is performed.

Solutions :
1.Disconnect and then connect the connector (J206) on the DC Controller PCB (PCB4).
2.Replace the Exhaust Fan (Front) (FAN4).
3.Replace the DC Controller PCB (PCB4).




Remember that, not every error is completely identical. What fixes the complication one occasion may not fix it the next occasion. While the advice in this text originates from the service manual and usually ought to get your machine functioning, in some cases other variables might be in play.

If you’re looking over this blog post and have expertise in this error message and want to share make sure you leave a comment down below. Or, if you have read this article and have more questions then ask. If I have knowledge about the problem then I will respond.