Canon imageRUNNER 2535 E225 0000 Error Code

 

Canon imageRUNNER 2535 E225 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2535 E225 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2535 E225 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2535 E225 0000 Error Code

E225 0000
Description :

Causes :
The light intensity of the CCD during shading is under the specified level.


Solutions :
1.Disconnect and then connect the flexible cable.
2.Replace the flexible cable.
3.Replace the CCD Unit.
4.Replace the Relay PCB (PCB2).
5.Replace the Main Controller PCB (PCB1).


Remember that, not every error is precisely identical. What remedies the malfunction one time may possibly not eliminate it the next occasion. While the ideas in this posting is obtained from the service manual and normally should get your piece of equipment ready to go, on occasion additional variables can be in play.

If you’re looking over this page and have expertise in this error and would like to contribute be sure to leave a comment beneath. Or, if you have read this article and have further questions then ask. If I have exposure to the difficulty then I will respond.