Below you will find the service manual information for the Canon imageRUNNER 2022 E261 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2022 E261 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2022 E261 0000 Error Code

E261 0000
Description :
Zero-cross signal error

Causes :
If failed to detect zero-cross signal cycle of the power supply when initializing.
When the input of the zero-signal failed continuously for three seconds while controlling the temperature adjustment.

Solutions :
Replace the power supply PCB.
Replace the DC controller PCB.




Try to remember, not every error is simply the same. What corrects the complication one occasion might not take care of it the next time. While the material in this blog post obtain from the service manual and typically should get your piece of equipment working, sometimes additional circumstances may be in play.