Canon imageRUNNER 2018 E261 0000 Error Code

 

Canon imageRUNNER 2018 E261 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 2018 E261 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 2018 E261 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 2018 E261 0000 Error Code

E261 0000
Description :
Zero-cross signal error

Causes :
If failed to detect zero-cross signal cycle of the power supply when initializing.
When the input of the zero-signal failed continuously for three seconds while controlling the temperature adjustment.

Solutions :
Replace the power supply PCB.
Replace the DC controller PCB.




Understand, not every error is simply alike. What treats the situation one occasion may not take care of it the next time. While the info in this posting comes from the service manual and typically ought to get your equipment working, at times other factors could possibly be in play.

If you are looking over this document and have experience with this problem and wish to contribute make sure you leave a comment underneath. Or, if you have read this article and have additional questions then ask. If I have exposure to the issue then I will reply.

We will be happy to hear your thoughts

Leave a reply

Shopping cart