Canon imageRUNNER 1750 E530 8002 Error Code

 

Canon imageRUNNER 1750 E530 8002 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 1750 E530 8002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1750 E530 8002 Error Code

Service Manual Instructions for the Canon imageRUNNER 1750 E530 8002 Error Code

E530 8002
Description :
Front Alignment Motor (M4) error

Causes :
At initialization of the Front Alignment Plate, the Front Alignment Plate failed to be detected by the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 0.78 seconds.

Solutions :
1. Check the connector connection of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
2. Check for open circuit of the Harness of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
3. Replace the Front Alignment Plate HP Sensor (S4).
4. Replace the Front Alignment Motor (M4).
5. Replace the Finisher Controller PCB.


Keep in mind, not every error is entirely alike. What fixes the malfunction one time may not eliminate it the next occasion. While the tips in this blog derives from the service manual and usually ought to get your machine functioning, at times other factors may be in play.

If you are reading this blog post and have expertise in this fault and wish to contribute make sure you leave a comment down the page. Or, if you have read this article and have more questions then ask. If I have experience with the difficulty then I will respond.

We will be happy to hear your thoughts

Leave a reply