Below you will find the service manual information for the Canon imageRUNNER 1750 E240 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it.Â
Service Manual Instructions for the Canon imageRUNNER 1750 E240 0000 Error Code
E240 0000
Description :
Controller communication error
Causes :
A serial communication error was detected during normal operation.
Solutions :
1. Check the connector connection. (All connectors on the DC Controller PCB, J8112 on the Main Controller PCB)
2. Replace the DC Controller PCB (PCB1).
Keep in mind, not every error is absolutely alike. What remedies the condition one occasion might not take care of it the next occasion. While the advice in this blog hails from the service manual and in most cases ought to get your machine up and running, in some cases additional variables can be in play.
If you are reading this article and have exposure to this error message and would wish to contribute you should leave a comment underneath. Or, if you have read this article and have further questions then ask. If I have exposure to the issue then I will answer.