Canon imageRUNNER 1750 E001 0002 Error Code

 

Canon imageRUNNER 1750 E001 0002 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 1750 E001 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1750 E001 0002 Error Code

Service Manual Instructions for the Canon imageRUNNER 1750 E001 0002 Error Code

E001 0002
Description :
Detection of overheating of Fixing Assembly

Causes :
The Sub Thermistor detected 295 deg C or higher for 200msec or longer on end.

Solutions :
1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).


Canon FM1-B701-000 Fuser (Fixing) Unit – 110 / 120 Volt (Genuine) – $279.95

from: Precision Roller

Canon imageRUNNER 1730 E000, E001, E002, E003, Error Code Reset


Canon imageRUNNER 1730 Fuser Removal and Replacement

Just remember, not every error is precisely the same. What treats the difficulty one occasion may possibly not remedy it the next time. While the details in this document is obtained from the service manual and oftentimes should get your piece of equipment functioning, now and again other factors might be in play.

If you are looking over this write-up and have expertise in this error and desire to share be sure to leave a comment beneath. Or, if you have read this article and have additional questions then ask. If I have experience with the situation then I will reply.

We will be happy to hear your thoughts

Leave a reply

Shopping cart