Canon imageRUNNER 1740iF E001 0000 Error Code

 

Canon imageRUNNER 1740iF E001 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 1740iF E001 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1740iF E001 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 1740iF E001 0000 Error Code

E001 0000
Description :
Detection of overheating of Fixing Assembly

Causes :
The Main Thermistor detected 250 deg C or higher for 200 msec or longer on end.

Solutions :
1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).


Canon FM1-B701-000 Fuser (Fixing) Unit – 110 / 120 Volt (Genuine) – $279.95

from: Precision Roller

Canon imageRUNNER 1730 E000, E001, E002, E003, Error Code Reset


Canon imageRUNNER 1730 Fuser Removal and Replacement

Don’t forget, not every error is entirely identical. What treats the malfunction one time may not get rid of it the next time. While the details in this writing originates from the service manual and oftentimes should get your unit operating, from time to time other variables could possibly be in play.

If you are looking over this page and have knowledge about this fault and wish to contribute please make sure to leave a comment down below. Or, if you have read this article and have further questions then ask. If I have exposure to the issue then I will respond.

We will be happy to hear your thoughts