Canon imageRUNNER 1740 E530 8001 Error Code

 

Canon imageRUNNER 1740 E530 8001 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 1740 E530 8001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1740 E530 8001 Error Code

Service Manual Instructions for the Canon imageRUNNER 1740 E530 8001 Error Code

E530 8001
Description :
Front Alignment Motor (M4) error

Causes :
At initialization of the Front Alignment Plate, the Front Alignment Plate failed to move from the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 10 mm.

Solutions :
1. Check the connector connection of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
2. Check for open circuit of the Harness of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
3. Replace the Front Alignment Plate HP Sensor (S4).
4. Replace the Front Alignment Motor (M4).
5. Replace the Finisher Controller PCB.


Do not forget, not every error is totally identical. What fixes the problem one time may possibly not solve it the next time. While the tips in this posting is obtained from the service manual and oftentimes ought to get your piece of equipment up and running, at times other factors might be in play.