Canon imageRUNNER 1740 E004 0000 Error Code

 

Canon imageRUNNER 1740 E004 0000 Error Code Instructions

Below you will find the service manual information for the Canon imageRUNNER 1740 E004 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1740 E004 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 1740 E004 0000 Error Code

E004 0000
Description :
Thermistor disconnection detection error

Causes :
Connector disconnection was detected for 30 msec on end.

Solutions :
1. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
2. Replace the Fixing Assembly.
3. Replace the DC Controller PCB (PCB1).



Canon FM1-B701-000 Fuser (Fixing) Unit – 110 / 120 Volt (Genuine) – $279.95

from: Precision Roller

Canon imageRUNNER 1730 E000, E001, E002, E003, Error Code Reset


Canon imageRUNNER 1730 Fuser Removal and Replacement

Do not forget, not every error is completely the same. What treats the condition one time might not fix it the next occasion. While the tips in this text obtain from the service manual and usually ought to get your product functioning, on occasion other elements could possibly be in play.

If you are looking at this write-up and have knowledge of this error and wish to contribute please leave a comment down the page. Or, if you have read this article and have further questions then ask. If I have information about the trouble then I will answer.

We will be happy to hear your thoughts

Leave a reply