Below you will find the service manual information for the Canon imageRUNNER 1740 E001 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1740 E001 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 1740 E001 0000 Error Code

E001 0000
Description :
Detection of overheating of Fixing Assembly

Causes :
The Main Thermistor detected 250 deg C or higher for 200 msec or longer on end.

Solutions :
1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).


Canon FM1-B701-000 Fuser (Fixing) Unit – 110 / 120 Volt (Genuine) – $279.95

from: Precision Roller

Canon imageRUNNER 1730 E000, E001, E002, E003, Error Code Reset


Canon imageRUNNER 1730 Fuser Removal and Replacement

Do not forget, not every error is completely identical. What remedies the condition one occasion might not resolve it the next occasion. While the info in this article hails from the service manual and most likely should get your equipment operating, on occasion other things can be in play.

If you are looking at this write-up and have information about this problem and wish to share be sure to leave a comment beneath. Or, if you have read this article and have further questions then ask. If I have information about the issue then I will answer back.

We will be happy to hear your thoughts

Leave a reply

Shopping cart