Below you will find the service manual information for the Canon imageRUNNER 1740 E000 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1740 E000 0001 Error Code

Service Manual Instructions for the Canon imageRUNNER 1740 E000 0001 Error Code

E000 0001
Description :
Fixing temperature rising error

Causes :
The detected temperature of the Main Thermistor failed to reach the specified temperature at temperature rising control.

Solutions :
1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).


Canon FM1-B701-000 Fuser (Fixing) Unit – 110 / 120 Volt (Genuine) – $279.95

from: Precision Roller

Canon imageRUNNER 1730 E000, E001, E002, E003, Error Code Reset


Canon imageRUNNER 1730 Fuser Removal and Replacement

Do not forget, not every error is completely identical. What fixes the malfunction one time might not solve it the next occasion. While the guidance in this page is inspired by the service manual and oftentimes ought to get your piece of equipment operating, on occasion other elements can be in play.

If you are looking at this write-up and have information about this malfunction and want to contribute please be sure to leave a comment below. Or, if you have read this article and have additional questions then ask. If I have information about the issue then I will reply.

We will be happy to hear your thoughts

Leave a reply

Shopping cart