Below you will find the service manual information for the Canon imageRUNNER 1730iF E001 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1730iF E001 0000 Error Code

Service Manual Instructions for the Canon imageRUNNER 1730iF E001 0000 Error Code

E001 0000
Description :
Detection of overheating of Fixing Assembly

Causes :
The Main Thermistor detected 250 deg C or higher for 200 msec or longer on end.

Solutions :
1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).


Canon FM1-B701-000 Fuser (Fixing) Unit – 110 / 120 Volt (Genuine) – $279.95

from: Precision Roller

Canon imageRUNNER 1730 E000, E001, E002, E003, Error Code Reset


Canon imageRUNNER 1730 Fuser Removal and Replacement

Always remember, not every error is totally the same. What treats the situation one occasion might not eliminate it the next time. While the advice in this page is obtained from the service manual and most likely should get your equipment operating, now and again additional circumstances could possibly be in play.

If you are looking at this piece of content and have experience with this fault and would wish to make a contribution please be sure to leave a comment down below. Or, if you have read this article and have more questions then ask. If I have information about the issue then I will respond.

We will be happy to hear your thoughts

Leave a reply

Shopping cart