Below you will find the service manual information for the Canon imageRUNNER 1730 E530 8002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1730 E530 8002 Error Code

Service Manual Instructions for the Canon imageRUNNER 1730 E530 8002 Error Code

E530 8002
Description :
Front Alignment Motor (M4) error

Causes :
At initialization of the Front Alignment Plate, the Front Alignment Plate failed to be detected by the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 0.78 seconds.

Solutions :
1. Check the connector connection of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
2. Check for open circuit of the Harness of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4).
3. Replace the Front Alignment Plate HP Sensor (S4).
4. Replace the Front Alignment Motor (M4).
5. Replace the Finisher Controller PCB.


Always remember, not every error is precisely identical. What treats the difficulty one occasion may possibly not remedy it the next occasion. While the advice in this piece of content comes from the service manual and normally should get your machine up and running, sometimes other elements might be in play.