Below you will find the service manual information for the Canon-imageRUNNER-3530 E191 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3530 E191 0000 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3530 E191 0000 Error Code

E191 0000
Description :
There is an error in the communication with the high-voltage power supply.

Causes :
The data transmission/reception does not end normally 500 msec after the most recent transmission/reception of data ended normally.




Solutions :
Replace the high-voltage power supply.
Replace the DC controller PCB.



If you’re reading this blog post and have expertise in this malfunction and would wish to make a contribution please be sure to leave a comment down below. Or, if you have read this article and have more questions then ask. If I have exposure to the issue then I will answer back.

Take into account, not every error is exactly the same. What remedies the issue one time might not exactly take care of it the next time. While the ideas in this written piece is obtained from the service manual and in most cases should get your piece of equipment functioning, occasionally other elements could possibly be in play.