Below you will find the service manual information for the Canon-imageRUNNER-3530 E001 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3530 E001 0002 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3530 E001 0002 Error Code

E001 0002
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the sub thermistor.
Replace the DC controller PCB.


Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95

Canon imageRUNNER 3530 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3530 E000, E001, E002, E003, Error Code Reset

If you’re reading this article and have experience with this error message and would wish to contribute please make sure to leave a comment down below. Or, if you have read this article and have further questions then ask. If I have experience with the difficulty then I will reply.

Take into account, not every error is completely alike. What corrects the issue one occasion will possibly not resolve it the next time. While the guidance in this blog post is obtained from the service manual and oftentimes should get your product up and running, sometimes other elements could possibly be in play.

We will be happy to hear your thoughts

Leave a reply

Shopping cart