Canon-imageRUNNER-3045 E743 0000 Error Code

 

Canon-imageRUNNER-3045 E743 0000 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3045 E743 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3045 E743 0000 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3045 E743 0000 Error Code

E743 0000
Description :
There is an error in the DDI communication.

Causes :
An SCI error has occurred. The received data is faulty. A reception timeout condition has occurred. An SEQ timeout error has occurred.




Solutions :
Disconnect and then connect the flexible cable used to connect the reader unit and the printer unit.
Replace the following as necessary: flexible cable, reader controller PCB, main controller PCB.



If you’re looking over this write-up and have exposure to this fault and wish to make a contribution please be sure to leave a comment down below. Or, if you have read this article and have further questions then ask. If I have information about the trouble then I will answer.

Remember, not every error is totally the same. What fixes the malfunction one time may not eliminate it the next occasion. While the guidance in this short article is obtained from the service manual and typically should get your device operating, occasionally additional factors may be in play.

We will be happy to hear your thoughts