Canon-imageRUNNER-3045 E001 0002 Error Code

 

Canon-imageRUNNER-3045 E001 0002 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3045 E001 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3045 E001 0002 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3045 E001 0002 Error Code

E001 0002
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the sub thermistor.
Replace the DC controller PCB.


Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95

Canon imageRUNNER 3045 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3045 E000, E001, E002, E003, Error Code Reset

If you’re looking over this piece of content and have exposure to this error message and would wish to make a contribution be sure to leave a comment down the page. Or, if you have read this article and have additional questions then ask. If I have knowledge about the trouble then I will respond.

Remember, not every error is absolutely identical. What corrects the malfunction one time may possibly not take care of it the next occasion. While the ideas in this writing derives from the service manual and in most cases ought to get your product up and running, now and again other elements might be in play.

We will be happy to hear your thoughts

Leave a reply

Shopping cart