Canon-imageRUNNER-3045 E001 0001 Error Code

 

Canon-imageRUNNER-3045 E001 0001 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3045 E001 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3045 E001 0001 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3045 E001 0001 Error Code

E001 0001
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
The hardware circuit detects overheating of the main or sub thermistor for 200 msec.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the DC controller PCB.



Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95

Canon imageRUNNER 3045 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3045 E000, E001, E002, E003, Error Code Reset

If you’re looking over this piece of content and have exposure to this error message and desire to make a contribution please make sure to leave a comment beneath. Or, if you have read this article and have more questions then ask. If I have knowledge about the issue then I will reply.

Remember, not every error is absolutely identical. What corrects the complication one occasion will possibly not remedy it the next occasion. While the advice in this posting is taken from the service manual and in most cases should get your equipment ready to go, sometimes other reasons might be in play.