Below you will find the service manual information for the Canon-imageRUNNER-3045 E001 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3045 E001 0000 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3045 E001 0000 Error Code

E001 0000
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
The reading of the main thermistor is 250 deg C or more continuously for 200 msec.




Solutions :
Reset the condition in service mode:COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor.
Replace the DC controller PCB.


Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95

Canon imageRUNNER 3045 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3045 E000, E001, E002, E003, Error Code Reset

If you’re looking over this piece of content and have exposure to this error and would like to contribute please leave a comment beneath. Or, if you have read this article and have additional questions then ask. If I have knowledge about the difficulty then I will answer.

Remember, not every error is absolutely alike. What remedies the trouble one occasion will possibly not solve it the next time. While the data in this write-up derives from the service manual and most often ought to get your product ready to go, sometimes additional circumstances can be in play.