Canon-imageRUNNER-3030 E001 0002 Error Code

 

Canon-imageRUNNER-3030 E001 0002 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3030 E001 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3030 E001 0002 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3030 E001 0002 Error Code

E001 0002
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the sub thermistor.
Replace the DC controller PCB.


Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95

Canon imageRUNNER 3030 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3030 E000, E001, E002, E003, Error Code Reset