Canon-imageRUNNER-3030 E000 0001 Error Code Instructions
Below you will find the service manual information for the Canon-imageRUNNER-3030 E000 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it.Â
Service Manual Instructions for the Canon-imageRUNNER-3030 E000 0001 Error Code
E000 0001
Description :
The temperature of the fixing assembly is abnormally high.
Causes :
While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply.
The startup control does not end 30 sec after the start of power supply.
Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor.
Replace the DC controller PCB.
Canon FM3-1293-020 Fuser (Fixing) Unit – 120 Volt (Genuine) – $599.95
Canon imageRUNNER 3030 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000
Canon imageRUNNER 3030 E000, E001, E002, E003, Error Code Reset
If you’re looking at this document and have information about this error message and wish to make a contribution please be sure to leave a comment below. Or, if you have read this article and have further questions then ask. If I have experience with the situation then I will respond.
Please remember, not every error is entirely identical. What fixes the condition one time might not exactly remedy it the next occasion. While the info in this write-up is taken from the service manual and most often should get your unit ready to go, in some cases other reasons might be in play.