Below you will find the service manual information for the Canon-imageRUNNER-3025N E100 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3025N E100 0001 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3025N E100 0001 Error Code

E100 0001
Description :
The BD interval is outside a specific range.

Causes :
After the machine has become ready for image formation (i.e., the scanner motor is ready for operation, and the laser has been turned on), an error has occurred 50 times or more (BD error).




Solutions :
Replace the laser unit.
Replace the DC controller PCB.
Check the wiring.


If you are reading this write-up and have exposure to this error and desire to share make sure you leave a comment underneath. Or, if you have read this article and have further questions then ask. If I have experience with the issue then I will reply.

Note, not every error is entirely identical. What treats the situation one occasion may not fix it the next occasion. While the material in this post is taken from the service manual and normally should get your device up and running, at times other variables could possibly be in play.