Canon-imageRUNNER-3025N E003 0000 Error Code

 

Canon-imageRUNNER-3025N E003 0000 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3025N E003 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3025N E003 0000 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3025N E003 0000 Error Code

E003 0000
Description :
The fixing temperature is too low after a standby state.

Causes :
While regular temperature control is under way, the reading of the main thermistor is less than 140 deg C continuously for 400 msec or more.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor.
Replace the DC controller PCB.


Canon FM3-1278-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $549.95

Canon imageRUNNER 3025N Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3025N E000, E001, E002, E003, Error Code Reset

If you are reading this short article and have exposure to this malfunction and would wish to make a contribution make sure you leave a comment down below. Or, if you have read this article and have further questions then ask. If I have knowledge about the issue then I will reply.

Note, not every error is completely alike. What corrects the malfunction one time may possibly not resolve it the next occasion. While the help and advice in this writing is inspired by the service manual and generally should get your piece of equipment functioning, from time to time additional factors may be in play.