Canon-imageRUNNER-3025N E000 0001 Error Code

 

Canon-imageRUNNER-3025N E000 0001 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-3025N E000 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3025N E000 0001 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3025N E000 0001 Error Code

E000 0001
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply.
The startup control does not end 30 sec after the start of power supply.

Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor.
Replace the DC controller PCB.


Canon FM3-1278-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $549.95

Canon imageRUNNER 3025N Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3025N E000, E001, E002, E003, Error Code Reset

If you are reading this short article and have expertise in this error message and wish to make a contribution please make sure to leave a comment beneath. Or, if you have read this article and have further questions then ask. If I have exposure to the difficulty then I will respond.

Note, not every error is absolutely alike. What treats the situation one occasion might not get rid of it the next time. While the specifics in this blog originates from the service manual and generally should get your piece of equipment operational, sometimes additional circumstances might be in play.