Below you will find the service manual information for the Canon-imageRUNNER-3025 E003 0000 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3025 E003 0000 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3025 E003 0000 Error Code

E003 0000
Description :
The fixing temperature is too low after a standby state.

Causes :
While regular temperature control is under way, the reading of the main thermistor is less than 140 deg C continuously for 400 msec or more.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor.
Replace the DC controller PCB.


Canon FM3-1278-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $549.95

Canon imageRUNNER 3025 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3025 E000, E001, E002, E003, Error Code Reset

If you are reading this document and have information about this error and wish to make a contribution please be sure to leave a comment beneath. Or, if you have read this article and have additional questions then ask. If I have information about the issue then I will answer back.

Keep in mind, not every error is simply identical. What corrects the malfunction one time may possibly not remedy it the next occasion. While the data in this blog post is obtained from the service manual and most often ought to get your piece of equipment operating, on occasion other elements can be in play.

We will be happy to hear your thoughts

Leave a reply

Shopping cart