Below you will find the service manual information for the Canon-imageRUNNER-3025 E000 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-3025 E000 0001 Error Code

Service Manual Instructions for the Canon-imageRUNNER-3025 E000 0001 Error Code

E000 0001
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply.
The startup control does not end 30 sec after the start of power supply.

Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor.
Replace the DC controller PCB.


Canon FM3-1278-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $549.95

Canon imageRUNNER 3025 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 3025 E000, E001, E002, E003, Error Code Reset

If you are reading this document and have expertise in this error and would like to contribute you should leave a comment down the page. Or, if you have read this article and have further questions then ask. If I have experience with the difficulty then I will answer back.

Keep in mind, not every error is precisely the same. What treats the difficulty one time may possibly not fix it the next occasion. While the information in this article is inspired by the service manual and normally should get your unit up and running, from time to time other reasons could possibly be in play.

We will be happy to hear your thoughts

Leave a reply

Shopping cart