Below you will find the service manual information for the Canon-imageRUNNER-2230 E064 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-2230 E064 0002 Error Code

Service Manual Instructions for the Canon-imageRUNNER-2230 E064 0002 Error Code

E064 0002
Description :
The voltage of the power supply is faulty (high-voltage error).

Causes :
While output is being generated, the AD value of the primary DC voltage is 230 (DEC) or more for 100 msec 2 times in sequence.
(However, after output, it is not detected for 100 msec.)



Solutions :
Replace the high-voltage power supply.
Replace the DC controller PCB.



If you are looking at this article and have knowledge of this fault and would like to share please leave a comment down the page. Or, if you have read this article and have further questions then ask. If I have exposure to the situation then I will answer.

Always remember, not every error is completely the same. What fixes the trouble one time may not eliminate it the next time. While the tips in this piece of content is obtained from the service manual and in most cases ought to get your unit operating, sometimes additional factors may be in play.