Canon-imageRUNNER-2230 E001 0002 Error Code

 

Canon-imageRUNNER-2230 E001 0002 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-2230 E001 0002 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-2230 E001 0002 Error Code

Service Manual Instructions for the Canon-imageRUNNER-2230 E001 0002 Error Code

E001 0002
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.




Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Replace the sub thermistor.
Replace the DC controller PCB.


Canon FM3-1278-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $549.95

Canon imageRUNNER 2230 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 2230 E000, E001, E002, E003, Error Code Reset

If you are looking at this article and have expertise in this error and would wish to make a contribution you should leave a comment down the page. Or, if you have read this article and have more questions then ask. If I have experience with the trouble then I will reply.

Always remember, not every error is absolutely identical. What corrects the trouble one time might not remedy it the next occasion. While the advice in this text derives from the service manual and in most cases ought to get your equipment operating, in some cases other variables can be in play.