Canon-imageRUNNER-2230 E000 0001 Error Code

 

Canon-imageRUNNER-2230 E000 0001 Error Code Instructions

Below you will find the service manual information for the Canon-imageRUNNER-2230 E000 0001 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon-imageRUNNER-2230 E000 0001 Error Code

Service Manual Instructions for the Canon-imageRUNNER-2230 E000 0001 Error Code

E000 0001
Description :
The temperature of the fixing assembly is abnormally high.

Causes :
While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply.
The startup control does not end 30 sec after the start of power supply.

Solutions :
Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Replace the main thermistor.
Replace the DC controller PCB.


Canon FM3-1278-000 Fuser (Fixing) Unit – 120 Volt (Genuine) – $549.95

Canon imageRUNNER 2230 Fuser Removal and Replacement FM3-1278-000, FM2-0356-000


Canon imageRUNNER 2230 E000, E001, E002, E003, Error Code Reset

If you are looking at this article and have experience with this error message and would like to make a contribution please make sure to leave a comment down below. Or, if you have read this article and have additional questions then ask. If I have information about the difficulty then I will reply.

Always remember, not every error is absolutely alike. What corrects the problem one time might not resolve it the next occasion. While the details in this posting is taken from the service manual and typically ought to get your piece of equipment operational, sometimes other factors might be in play.